东京计器 TOKYO-KEIKI 电磁换向阀 DG4V-3 选型与说明
2017-02-18 17:40:55 来源:昆山瑞腾精密自动化有DIRECTIONAL VALVES - SOLENOID OPERATED DIRECTIONAL VALVES - DG4V-3 SERIES TOKYO.KEIKI 东京计器 DG4V-3 电磁换向阀 选型与说明
MODEL CODE
(F3) - DG4V - 3 - 2 A (L) - M - P 2 - T - 7 - (P08) - 56 - (JA16) 1 2 3 4 5 6 7 8 9 10 11 12 13 1. Fluid Omit for mineral oil, water glycol F3: phosphate ester 2. Wet armature directional valve 3. Mounting, ISO4401-03 4. Spool type 5. Spring set A: spring offset A type (2 position, single sol.) B: spring offset B type (2 position, single sol.) C: spring centered (3 position, dual sol.) N: no spring detent (2 position, dual sol.) 6. Solenoid assembly direction Omit for st'd (energized, P to B, A to T) L: left hand assembly (energized, P to A, B to T) 7. Wiring connection P: plug-in conduit box G1/2 (PF1/2) U: DIN43650 connector KU: lead wire 8. Elec. accessories Omit for no accessories (P, W, J) 1: no accessories (U) 2: indicator lamp (AC st'd) 4: surge supressor 7: indicator lamp and surge suppressor (DC st'd) 9: ADC rectifier (quick deenergize) and indicator lamp 12: ADC rectifier (slow deenergize) and indicator lamp 9. Solenoid voltage T: 100 V 50/60 Hz, 110 V 60 Hz V: 200 V 50/60 Hz, 220 V 60 Hz G: DC12 V H: DC24 V TR: 100 V 50/60 Hz (ADC rectifier) VR: 200 V 50/60 Hz (ADC rectifier) 10. T port allowable back pressure 7: 20.6 MPa 11. Port orifice Omit for no port orifice (st'd) 12. Design no. 13. Special feature JA16: man. operated knob SPECIFICATIONS
Model Max.
Press.
(MPa)Max. Flow
(L/min)Tank Port
Backpress.
(MPa)Max. Shift. Freq.
(times / min.)Mass (kg) Single
Sol.Double
Sol.AC DC ADC DG4V-3 35 consult mfr. 20.6 300 300 120 AC
1.6DC
1.7AC
2.0DC
2.1SOLENOID SPECIFICATIONS
Power Volt.
CodeVolt.
(V)Freq.
(Hz)Start.
Current
(A)Holding
Current
(A)Power
Consump.
(W)Allow.
Volt. Fluct.
(%)Insul.
Class(AC) T 100 50 1.8 0.52 23 +10, -15 H type
(180)60 1.4 0.40 20 +20, -10 110 60 1.6 0.46 24 +10, -15 B110 50 1.6 0.47 23 +10, -15 115 60 1.3 0.36 22 +15, -10 120 60 1.5 0.42 24 +10, -15 V 200 50 0.9 0.26 23 +10, -15 60 0.7 0.20 20 +20, -10 220 60 0.8 0.23 24 +10, -15 D 220 50 0.8 0.24 23 +10, -15 230 60 0.65 0.18 22 +15, -10 240 60 0.75 0.21 24 +10, -15 (DC) G 12 - - 2.40 29 ±10 H type
(180)H 24 1.16 28 J 48 0.6 29 R 100 0.34 34 AC->DC
(rectified)
(ADC)TR AC100 V50/60Hz
->DC90 V (coil)- 0.37 34 ±10 H type
(180)VR AC200 V50/60Hz
->DC180 V (coil)0.20 36